GP-4100 Series Hardware Manual
4-4
When installing the GP in a slanted panel, the panel face should not incline more than 30°.
When installing the GP in a slanted panel, and the panel face inclines more than 30°, the ambient
temperature must not exceed 40°C. You may need to use forced air cooling (fan, A/C) to ensure the
ambient operating temperature is 40°C or below.
When mounting the GP unit vertically, ensure that the left side of the unit faces up (i.e. the power
connector and serial interface should be at the bottom).
30° or less
Mounted
Horizontally
Front and Rear Views
when Mounted Vertically
(RS-422/485 Type)